Only ENDOPATH XCEL Trocars with OPTIVIEW Technology
Reduce smudging upon endoscope reinsertion, time after time.
Made with the Camera Port in Mind
Not all ports require the same level of trocar functionality. That's why Ethicon developed a portfolio of trocars that offers the flexibility to choose the right trocar for the right level of performance…when and where it’s needed.
ENDOPATH XCEL Trocars with OPTIVIEW Technology are designed to reduce smudging of the endoscope upon reinsertion by wiping, wicking, and absorbing fluid that builds up inside the trocar seal housing.*
Frustrated by constantly having to reclean your endoscope?
The repeated smudging of the endoscope lens that occurs when it is reinserted into a trocar (after just being cleaned) is a common frustration among surgeons.
Smudging upon endoscope reinsertion
Necessitates frequent re-wiping
May disrupt procedural flow
May lead to surgeon distractions
ENDOPATH XCEL Trocars with OPTIVIEW Technology cut endoscope re-wipes in half*
Most effective smudge mitigation vs. leading trocars
Reducing smudging means less re-wipes*
5mm Trocars
At least 59% more effective than Covidien Versaport™ and VersaStep™ Bladeless Trocars
At least 58% more effective than Applied Medical Kii® and Kii® Fios® Trocars
12mm Trocars
At least 66% more effective than Covidien VersaPort™ and VersaStep™ Bladeless Trocars
At least 74% more effective than Applied Medical Kii® and Kii® Fios® Trocars
Designed to allow you to concentrate on the procedure (not the trocar)
See how ENDOPATH XCEL Trocar with OPTIVIEW Technology is the most effective at reducing smudging during endoscope/scope reinsertion.* Only OPTIVIEW® Technology wipes bodily fluid off the endoscope shaft, wicks it away and absorbs it.
* Comparing mean number of insertions for 5mm trocars out of 10 insertions with a quality index score of 92 or higher for 2B5LT (6.4 insertions) to C0Q04/CFR03/CTR03/CTF03/CFI13 (0.5 insertions), NB5STF/VS101005 (0.4 insertions) in bench top tests, p-value <0.05. Data on File - Study PRC049012
Comparing mean number of insertions for 12mm trocars out of 15 insertions with a quality index score of 92 or higher for 2B12LT (11.6 insertions) to CTF73/C0R29/CFI83/CFF73/CFR73/C0R47 (.4 insertions), NB12STF/VS101012P (1.6 insertions) in bench top tests, p-value <0.05. Data on File - Study PRC056628.
Quality index score of 92 or higher indicates a less than 20% chance of having to re-wipe the endoscope lens due to trocar induced smudging.
The Key Benefits of ENDOPATH XCEL Trocars Now With OPTIVIEW Technology
Designed for the camera port, the ENDOPATH XCEL Trocar with OPTIVIEW Technology is the only trocar that reduces smudging of the endoscope upon reinsertion by wiping, wicking and absorbing fluid that can build up inside the trocar housing.*
Product Description
The ENDOPATH XCEL Trocar with OPTIVIEW Technology is a sterile single patient use instrument consisting of a radiolucent sleeve and bladeless obturator in sizes 5 mm and 12 mm diameter. The bladeless obturator contains a clear, tapered optical element. The 5 mm and 12 mm diameter bladeless obturators accommodate an appropriately sized 0º endoscope and provide visibility of individual tissue layers during insertion. OPTIVIEW Technology keeps bodily fluids away from the camera during reinsertion to offer smudge mitigation during camera reinsertion, to minimize interruptions, and to preserve procedural flow.
ENDOPATH XCEL Trocars with OPTIVIEW Technology are available in 5mm and 12mm sizes in bladeless tip, dilating tip, blunt tip (12mm only) and universal sleeve.
ENDOPATH® XCEL® Bladeless Trocars with OPTIVIEW® Technology
PRODUCT CODE
DIAMETER
LENGTH
SLEEVE
EA/BX
2B5LT
5mm
100mm
Stability
6
2B5ST
5mm
75mm
Stability
6
2B5XT
5mm
150mm
Stability
6
2B12LT
12mm
100mm
Stability
6
2B12XT
12mm
150mm
Stability
6
ENDOPATH® XCEL® Dilating Tip Trocars with OPTIVIEW® Technology
PRODUCT CODE
DIAMETER
LENGTH
SLEEVE
EA/BX
2D5LT
5mm
100mm
Stability
6
2D5ST
5mm
75mm
Stability
6
2D12LT
12mm
100mm
Stability
6
2D12XT
12mm
150mm
Stability
6
ENDOPATH® XCEL® Blunt Tip Trocars with OPTIVIEW® Technology
PRODUCT CODE
DIAMETER
LENGTH
SLEEVE
EA/BX
2H12LP
12mm
100mm
Stability
6
ENDOPATH® XCEL® Universal Sleeves with OPTIVIEW® Technology
PRODUCT CODE
DIAMETER
LENGTH
SLEEVE
EA/BX
2CB5LT
5mm
100mm
Stability
6
2CB5ST
5mm
75mm
Stability
6
2CB12LT
12mm
100mm
Stability
6
*Comparing mean number of insertions for 5mm trocars out of 10 insertions with a quality index score of 92 or higher for 2B5LT (6.4 insertions) to C0Q04/CFR03/CTR03/CTF03/CFI13 (0.5 insertions), NB5STF/VS101005 (0.4 insertions) in bench top tests, p-value <0.05. Data on File - Study PRC049012.
Comparing mean number of insertions for 12mm trocars out of 15 insertions with a quality index score of 92 or higher for 2B12LT (11.6 insertions) to CTF73/C0R29/CFI83/CFF73/CFR73/C0R47 (.4 insertions), NB12STF/VS101012P (1.6 insertions) in bench top tests, p-value <0.05. Data on File - Study PRC056628.
Quality index score of 92 or higher indicates a less than 20% chance of having to re-wipe the endoscope lens due to trocar induced smudging.
† Clinical situations compromising fascial reapproximation (such as port site enlargement excessive manipulation or trocar reinsertion) may based on the surgeon’s clinical judgment dictate fascial closure. Not Applicable to 15mm ENDOPATH® XCEL® Trocars.
‡ McCarus SD et al. Gynecological Laparoscopy: Improving Laparoscopic Herniation Outcomes without Trocar Site Fascial Closure: A Multicenter Trial. Abstract presented at 2004 ACS and AAGL.
Looking for more specific instruction regarding our devices? Here are various materials and media to explain and walk you through the proper steps for their use. For the full steps to use of any of our devices, please refer to the package insert.