ENDOPATH XCEL® Trocars with OPTIVIEW® Technology

ENDOPATH XCEL® Trocars with OPTIVIEW® Technology

ENDOPATH XCEL® Trocars with OPTIVIEW® Technology

Overview

Only ENDOPATH XCEL Trocars with OPTIVIEW Technology

Reduce smudging upon endoscope reinsertion, time after time.

Trocar with Callouts

Made with the camera port in mind

Not all ports require the same level of trocar functionality. That's why Ethicon developed a portfolio of trocars that offers the flexibility to choose the right trocar for the right level of performance…when and where it’s needed.

ENDOPATH XCEL Trocars with OPTIVIEW Technology are designed to reduce smudging of the endoscope upon reinsertion by wiping, wicking, and absorbing fluid that builds up inside the trocar seal housing.*

Frustrated by constantly having to reclean your endoscope?

The repeated smudging of the endoscope lens that occurs when it is reinserted into a trocar (after just being cleaned) is a common frustration among surgeons.

Smudging upon endoscope reinsertion

  • Necessitates frequent re-wiping
  • May disrupt procedural flow
  • May lead to surgeon distractions

ENDOPATH XCEL Trocars with OPTIVIEW Technology cut endoscope re-wipes in half*

Most effective smudge mitigation vs. leading trocars

Reducing smudging means less re-wipes*

5mm Trocars

5mm Trocars

  • At least 59% more effective than Covidien Versaport™ and VersaStep™ Bladeless Trocars
  • At least 58% more effective than Applied Medical Kii® and Kii® Fios® Trocars
12mm Trocars

12mm Trocars

  • At least 66% more effective than Covidien VersaPort™ and VersaStep™ Bladeless Trocars
  • At least 74% more effective than Applied Medical Kii® and Kii® Fios® Trocars

Designed to allow you to concentrate on the procedure (not the trocar)

See how ENDOPATH XCEL Trocar with OPTIVIEW Technology is the most effective at reducing smudging during endoscope/scope reinsertion.* Only OPTIVIEW® Technology wipes bodily fluid off the endoscope shaft, wicks it away and absorbs it.

Request Rep Follow-up
  • * Comparing mean number of insertions for 5mm trocars out of 10 insertions with a quality index score of 92 or higher for 2B5LT (6.4 insertions) to C0Q04/CFR03/CTR03/CTF03/CFI13 (0.5 insertions), NB5STF/VS101005 (0.4 insertions) in bench top tests, p-value <0.05. Data on File – Study PRC049012
  • Comparing mean number of insertions for 12mm trocars out of 15 insertions with a quality index score of 92 or higher for 2B12LT (11.6 insertions) to CTF73/C0R29/CFI83/CFF73/CFR73/C0R47 (.4 insertions), NB12STF/VS101012P (1.6 insertions) in bench top tests, p-value <0.05. Data on File – Study PRC056628.
  • Quality index score of 92 or higher indicates a less than 20% chance of having to re-wipe the endoscope lens due to trocar induced smudging.
Description & Specs

The key benefits of ENDOPATH XCEL Trocars now with OPTIVIEW Technology

Designed for the camera port, the ENDOPATH XCEL Trocar with OPTIVIEW Technology is the only trocar that reduces smudging of the endoscope upon reinsertion by wiping, wicking and absorbing fluid that can build up inside the trocar housing.*

Product description

The ENDOPATH XCEL Trocar with OPTIVIEW Technology is a sterile single patient use instrument consisting of a radiolucent sleeve and bladeless obturator in sizes 5 mm and 12 mm diameter. The bladeless obturator contains a clear, tapered optical element. The 5 mm and 12 mm diameter bladeless obturators accommodate an appropriately sized 0º endoscope and provide visibility of individual tissue layers during insertion. OPTIVIEW Technology keeps bodily fluids away from the camera during reinsertion to offer smudge mitigation during camera reinsertion, to minimize interruptions, and to preserve procedural flow.

ENDOPATH XCEL Trocars with OPTIVIEW Technology are available in 5mm and 12mm sizes in bladeless tip, dilating tip, blunt tip (12mm only) and universal sleeve.

Fact Sheet
ENDOPATH XCEL® Bladeless Trocars with OPTIVIEW® Technology
PRODUCT CODE DIAMETER LENGTH SLEEVE EA/BX
2B5LT 5mm 100mm Stability 6
2B5ST 5mm 75mm Stability 6
2B5XT 5mm 150mm Stability 6
2B12LT 12mm 100mm Stability 6
2B12XT 12mm 150mm Stability 6
ENDOPATH XCEL® Dilating Tip Trocars with OPTIVIEW® Technology
PRODUCT CODE DIAMETER LENGTH SLEEVE EA/BX
2D5LT 5mm 100mm Stability 6
2D5ST 5mm 75mm Stability 6
2D12LT 12mm 100mm Stability 6
2D12XT 12mm 150mm Stability 6
ENDOPATH XCEL® Blunt Tip Trocars with OPTIVIEW® Technology
PRODUCT CODE DIAMETER LENGTH SLEEVE EA/BX
2H12LP 12mm 100mm Stability 6
ENDOPATH XCEL® Universal Sleeves with OPTIVIEW® Technology
PRODUCT CODE DIAMETER LENGTH SLEEVE EA/BX
2CB5LT 5mm 100mm Stability 6
2CB5ST 5mm 75mm Stability 6
2CB12LT 12mm 100mm Stability 6
  • *Comparing mean number of insertions for 5mm trocars out of 10 insertions with a quality index score of 92 or higher for 2B5LT (6.4 insertions) to C0Q04/CFR03/CTR03/CTF03/CFI13 (0.5 insertions), NB5STF/VS101005 (0.4 insertions) in bench top tests, p-value <0.05. Data on File – Study PRC049012.
  • Comparing mean number of insertions for 12mm trocars out of 15 insertions with a quality index score of 92 or higher for 2B12LT (11.6 insertions) to CTF73/C0R29/CFI83/CFF73/CFR73/C0R47 (.4 insertions), NB12STF/VS101012P (1.6 insertions) in bench top tests, p-value <0.05. Data on File – Study PRC056628.
  • Quality index score of 92 or higher indicates a less than 20% chance of having to re-wipe the endoscope lens due to trocar induced smudging.
  • Clinical situations compromising fascial reapproximation (such as port site enlargement excessive manipulation or trocar reinsertion) may based on the surgeon’s clinical judgment dictate fascial closure. Not Applicable to 15mm ENDOPATH® XCEL® Trocars.
  • McCarus SD et al. Gynecological Laparoscopy: Improving Laparoscopic Herniation Outcomes without Trocar Site Fascial Closure: A Multicenter Trial. Abstract presented at 2004 ACS and AAGL.
Videos & Media

Developing OPTIVIEW® Technology (4 min 42 sec)

Learn how we worked with our customers to identify the frustration of having to re-wipe the endoscope due to trocar induced smudging and how only OPTIVIEW® Technology reduces the presence of bodily fluid, tissue, & debris within the trocar housing, which can cause smudging.

Video: Developing OPTIVIEW® Technology

Learn how we worked with our customers to identify the frustration of having to re-wipe the endoscope due to trocar induced smudging and how only OPTIVIEW® Technology reduces the presence of bodily fluid, tissue, & debris within the trocar housing, which can cause smudging.
Developing OPTIVIEW® Technology

Learn how we worked with our customers to identify the frustration of having to re-wipe the endoscope due to trocar induced smudging and how only OPTIVIEW® Technology reduces the presence of bodily fluid, tissue, & debris within the trocar housing, which can cause smudging.

Video: ENDOPATH XCEL® Bladeless Trocar with OPTIVIEW® Technology Product in Use Animation

Watch this overview and walk through of the key steps for use of our ENDOPATH XCEL® Bladeless Tip Trocar with OPTIVIEW® Technology.
ENDOPATH XCEL® Bladeless Trocar with OPTIVIEW® Technology Product in Use Animation

Watch this overview and walk through of the key steps for use of our ENDOPATH XCEL® Bladeless Tip Trocar with OPTIVIEW® Technology.

Video: ENDOPATH XCEL® Dilating Tip Trocar with OPTIVIEW® Technology Product in Use Animation

Watch this overview and walk through of the key steps for use of our ENDOPATH XCEL® Dilating Tip Trocar with OPTIVIEW® Technology.
ENDOPATH XCEL® Dilating Tip Trocar with OPTIVIEW® Technology Product in Use Animation

Watch this overview and walk through of the key steps for use of our ENDOPATH XCEL® Dilating Tip Trocar with OPTIVIEW® Technology.

Video: ENDOPATH XCEL® Trocars with OPTIVIEW® Technology Overview

Learn how ENDOPATH XCEL® Trocars with OPTIVIEW® Technology reduces the presence of bodily fluid, tissue and debris within the trocar housing, which can cause smudging.
ENDOPATH XCEL® Trocars with OPTIVIEW® Technology Overview

Learn how ENDOPATH XCEL® Trocars with OPTIVIEW® Technology reduces the presence of bodily fluid, tissue and debris within the trocar housing, which can cause smudging.

Video: How Trocar Induced Smudging Occurs

Learn how fluid build-up in the trocar seals leads to the frustrating smudging of the endoscope lens upon reinsertion.
How Trocar Induced Smudging Occurs

Learn how fluid build-up in the trocar seals leads to the frustrating smudging of the endoscope lens upon reinsertion.

Video: Technology Demo Animation - ENDOPATH XCEL® Trocars with OPTIVIEW® Technology

Learn about the technology used in ENDOPATH XCEL® Trocars with OPTIVIEW® Technology. Only OPTIVIEW Technology reduces the presence of bodily fluid, tissue, & debris within the trocar housing, which can cause smudging.
Technology Demo Animation - ENDOPATH XCEL® Trocars with OPTIVIEW® Technology

Learn about the technology used in ENDOPATH XCEL® Trocars with OPTIVIEW® Technology. Only OPTIVIEW Technology reduces the presence of bodily fluid, tissue, & debris within the trocar housing, which can cause smudging.