ENSEAL® G2 Curved and Straight Tissue Sealers

ENSEAL® G2 Tissue Sealers, complete the ENSEAL Portfolio of advanced bi-polar tissue sealers

Strong on Sealing

  • More than twice the compression at the distal tip of the jaw than LigaSure 5mm*
  • More consistent seal strength over multiple activations than LigaSure 5mm
  • Seals vessels up to 7mm diameter and lymphatics

Gentle on Tissue

  • Less sticking over multiple activations than LigaSure 5mm§
  • Offset electrode configuration designed to minimize thermal spread

Site References

  • * In side-by-side benchtop testing, average compression of distal 0.11 in of jaws used in ENSEAL® G2 Curved was 187 psi (standard deviation 81 psi) and ENSEAL® G2 Straight was 104 psi (standard deviation 36 psi) vs. 42 psi (standard deviation 8 psi) for LigaSure 5mm, p<0.0000.
  • In a benchtop study with ENSEAL G2 Curved and Straight using 5mm porcine carotid arteries, vessel burst pressure was measured over 52 activation cycles, p<0.05.
  • Studies conducted on porcine mesentary.1
  • § Based on number of tissue sticking events during continuous resection of porcine mesentery model over five (5) minutes of use ENSEAL G2 Curved and Straight had a sticking rate of 1.6% or less vs. 10.6% for LigaSure 5mm (p<0.001).

The Ethicon ENSEAL G2 Tissue Sealers are sterile, single-patient-use surgical instruments for coagulating and transecting vessels up to and including 7mm in diameter, as well as lymphatics.*

Features include:

  • Jaw length: 20mm
  • Jaw type: Curved or Straight
  • Shaft lengths: 14cm, 25cm, 35cm or 45cm from jaw tip to rotation knob
  • Shaft diameter: 5mm
  • Power cord length: 3.1m
  • Ergonomically designed grip housing assembly
  • 360 degree rotating shaft
  • Atraumatic teeth for grasping and holding targeted tissue when clamped

The ENSEAL® G2 Tissue Sealers are compatible with the Ethicon Endo-Surgery Generator G11, sold separately.
Click here for more information on the Ethicon Endo-Surgery Generator.

Applicable specialties:

  • General
  • Colorectal
  • Gynecologic
  • Urologic
  • Thoracic
PRODUCT CODE SHAFT DIAMETER LENGTH EA/BX JAW
NSLG2C14 5mm 14cm 6 Curved
NSLG2C25 5mm 25cm 6 Curved
NSLG2C35 5mm 35cm 6 Curved
NSLG2C45 5mm 45cm 6 Curved
NSLG2S14 5mm 14cm 6 Straight
NSLG2S25 5mm 25cm 6 Straight
NSLG2S35 5mm 35cm 6 Straight
NSLG2S45 5mm 45cm 6 Straight

Site References

  • * Studies conducted on porcine mesentary.1

Looking for more specific instruction regarding our devices? Here are various materials and media to explain and walk you through the proper steps for their use. For the full steps to use of any of our devices, please refer to the package insert.

ENSEAL® Technology
Gentle on tissue. Strong on sealing.

ENSEAL Technology

ENSEAL® Devices bring a new level of assurance to sealing large vessels up to 7mm. The next generation ENSEAL® Technology delivers several sealing advancements.

I-BLADE® Technology delivers high uniform compression throughout device tips for seal consistency. Other bipolar devices rely solely on the force of initial jaw closure to provide compression – which results in a fall-off in force from the proximal to the distal end of the jaws.

Compression Animation
Temperature is controlled at the tissue interface

Temperature is controlled at the tissue interface

A polymer compound within the jaw uses Positive Temperature Coefficient (PTC) technology to modulate energy flow. It maintains a constant temperature of approximately 100°C, minimizing tissue sticking, charring and smoke.

PTC Animation
Offset electrodes help contain energy flow within jaws

Offset electrodes help contain energy flow within jaws

Other bipolar devices have simple positive and negative electrodes, which allow energy to spread significantly into surrounding tissue. ENSEAL® Devices feature a unique offset electrode design, which helps contain energy flow within the jaws, reducing lateral thermal spread to approximately 1mm.

Current Flow Animation