Home > Products > Surgical Stapling > Circular Staplers > ECHELON CIRCULAR™ Powered Stapler

ECHELON CIRCULAR™ Powered Stapler

The ECHELON CIRCULAR Powered Stapler is designed to reduce leaks without compromising perfusion—resulting in 61% fewer leaks at the staple line compared to the Medtronic DST Series™ EEA™ Stapler.*

3D Stapling Technology

Reduces potential leak paths

Designed with offset closure of the staple legs, 3D Stapling Technology evenly distributes compression throughout the anastomosis.

Download product brochure  picture_as_pdf
ECHELON CIRCULAR

Gripping Surface Technology

Gentler handling: reduces compressive forces on tissue by 33%

Gives precise compression only where it is needed to prepare the tissue for staple formation.

Watch: demonstrating two new technologies  video_library
ECHELON CIRCULAR

Powered firing platform

Reduces force to fire by 97%§

Push button firing significantly reduces movement at the distal tip for increased stability. It is designed to minimize variation in usage and standardize performance across users.

Watch video: the stability of power  video_library
ECHELON CIRCULAR


ECHELON CIRCULAR™ Powered Stapler
PRODUCT CODE DIAMETER QUANTITY SALES UNIT
CDH23P 23mm 3
CDH25P 25mm 3
CDH29P 29mm 3
CDH31P 31mm 3

Want to be the first to know when this product launches? Provide your email below and we'll keep you informed on all the latest updates, news and details.

By submitting the above information, you agree that the information you provide will be governed by the site's Privacy Policy
First Name:
Last Name:
Email:
Specialty:

Site References

  • * Benchtop testing in porcine tissue ≤30mmHg (26mmHg average pressure experienced during intra-operative leak test), comparing Ethicon CDH29P to Medtronic EEA2835 (p<0.001) and preclinical perfusion model, in which perfusion was not significantly different between devices.
  • † Staple line analysis in benchtop testing, comparing Ethicon CDH25P to Medtronic EEA2535.
  • ‡ Benchtop testing on porcine colon, comparing Ethicon CDH29P to Medtronic EEA2835, p<0.001.
  • § Benchtop testing, comparing Ethicon CDH29P to Medtronic EEA2835, p=0.001.
  • ‖ Users firing in a porcine model, comparing Ethicon CDH29P to Medtronic EEA2835, p=0.003.
X
Thanks for submitting the question. Thanks for submitting the question. Thanks for submitting the question. Thanks for submitting the question. on dev
X
Share with Friends

Interested in sharing this item?

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Image CAPTCHA
Enter the characters shown in the image.
X
Device Code Translator
X
Device code translator results

Back to Search