Home > Products > Surgical Stapling > Circular Staplers > Ethicon Circular Stapler

Ethicon Circular Stapler

The Ethicon Circular Stapler is designed to promote healing, more tissue control and less tension on the anastomosis, with distinct audible and tactile feedback during firing.

Promote healing

Allows the user to control the amount of compression applied depending on tissue conditions

Controlled Tissue Compression and Adjustable Height Staple Technology are designed to deliver optimal compression needed for a secure anastomosis and effective perfusion to promote healing.

Download product fact sheet   picture_as_pdf

More tissue control

Anvil shaft passes through tissue without catching as the device is closed

The continuously smooth anvil shaft creates less excess tissue draw during anvil closure compared to the Covidien DST SeriesTM EEATM.*

Learn More About Tissue Control   video_library

Less tension

Fixed anvil for predictable tissue interaction as device is opened

The solid, fixed anvil design causes less tension on the anastomosis with less strain on the staple line during opening compared to the Covidien DST Series EEA.¥

Learn More About Tension   video_library

More device feedback

Breakaway washer for distinct audible and tactile feedback during firing

The breakaway washer provides 5x more tactile feedback and 16x more audible feedback§ compared to the Covidien DST Series EEA.

Learn About Device Feedback   video_library
Ethicon Endoscopic Circular Stapler
PRODUCT CODE SHAFT LENGTH OPEN STAPLE HEIGHT COMPRESSED TISSUE THICKNESS RANGE † NUMBER OF STAPLES SIZE QUANTITY PER BOX
ECS21A 37cm 5.5mm 1.0-2.5mm 16 21mm 3
ECS25A 37cm 5.5mm 1.0-2.5mm 20 25mm 3
ECS29A 37cm 5.5mm 1.0-2.5mm 24 29mm 3
ECS33A 37cm 5.5mm 1.0-2.5mm 28 33mm 3
Ethicon Curved Open Circular Stapler
PRODUCT CODE SHAFT LENGTH OPEN STAPLE HEIGHT COMPRESSED TISSUE THICKNESS RANGE † NUMBER OF STAPLES SIZE QUANTITY PER BOX
CDH21A 26cm 5.5mm 1.0-2.5mm 16 21mm 3
CDH25A 26cm 5.5mm 1.0-2.5mm 20 25mm 3
CDH29A 26cm 5.5mm 1.0-2.5mm 24 29mm 3
CDH33A 26cm 5.5mm 1.0-2.5mm 28 33mm 3

Site References

  • * 3.9x less excess tissue draw in benchtop testing on porcine jejunum. Comparing mean tissue draw during anvil closing of the Ethicon Circular Stapler (CDH25A) and the DST Series™ EEA™ Circular Stapler (EEAXL25). 0.437cm vs 1.708cm, p<0.05
  • ¥1.4x less strain on the staple line in benchtop testing on porcine jejunum. Comparing mean tissue stretch during anvil opening after firing of the Ethicon Circular Stapler (CDH25A) and the DST Series™ EEA™ Circular Stapler (EEA25). 1.558cm vs 2.228cm, p<0.05
  • Benchtop testing comparing average vibration measured as mean vectorial acceleration during firing. CDH 16.58 m/s2 vs. EEA 3.20 m/s2
  • § Benchtop testing comparing mean peak sound intensity during firing. CDH 109.80 dB(linear) vs. EEA 95.27 dB(linear)
  • 1.0mm compressed tissue thickness provides 1.5mm closed staple height
X
Thanks for submitting the question. Thanks for submitting the question. Thanks for submitting the question. Thanks for submitting the question. on dev
X
Share with Friends

Interested in sharing this item?

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Image CAPTCHA
Enter the characters shown in the image.
X
Device Code Translator
X
Device code translator results

Back to Search