Uterine & Pelvic Surgery

GYNECARE INTERCEED® Absorbable Adhesion Barrier


Control beyond closure

GYNECARE INTERCEED Adhesion Barrier has been proven to reduce the formation of pelvic adhesions to provide you with control beyond closure. Extend the benefits of your meticulous surgical technique throughout the 5-to-7 day peritoneal tissue healing process to protect the pelvic organs from adhesion formation. With GYNECARE INTERCEED Adhesion Barrier, you can close with confidence.

4350 3" x 4" (7.6cm x 10.2cm) 10
4350XL 5" x 6" (12.7cm x 15.2cm) 10

Essential Product Information

    GYNECARE INTERCEED® Absorbable Adhesion Barrier is indicated as an adjuvant in open (laparotomy) gynecologic pelvic surgery for reducing the incidence of postoperative pelvic adhesions after meticulous hemostasis is achieved consistent with microsurgical principles.
    The use of GYNECARE INTERCEED®> (TC7) Absorbable Adhesion Barrier is contraindicated in the presence of frank infection. GYNECARE INTERCEED® is not indicated as a hemostatic agent. Appropriate means of achieving hemostasis must be employed.
    The safety and effectiveness of GYNECARE INTERCEED® in laparoscopic surgery or any procedures other than open (laparotomy) gynecologic microsurgical procedures have not been established.
    Postoperative adhesions may be induced by GYNECARE INTERCEED® application if adjacent tissues (eg, ovary and tube) and structures are coapted or conjoined by the device, or if GYNECARE INTERCEED® is folded, wadded or layered. Postoperative adhesions may occur in the presence of GYNECARE INTERCEED® if meticulous hemostasis is not achieved prior to application. As with all foreign substances, GYNECARE INTERCEED® should not be placed in a contaminated surgical site.
    Use only a single layer of GYNECARE INTERCEED®, since multiple layers of packing or folding will not enhance the adhesion barrier characteristics and may interfere with the absorption rate of GYNECARE INTERCEED®. Care should be exercised in applying GYNECARE INTERCEED® to a pelvic organ not to constrict or restrict it. If the product comes in contact with blood prior to completing the procedure, it should be discarded, as fibrin deposition cannot be removed by irrigation and may promote adhesions formation. Ectopic pregnancies have been associated with fertility surgery of the female reproductive tract. No data exist to establish the effect, if any, of GYNECARE INTERCEED® on the occurrence of ectopic pregnancies. No adequate studies have been conducted in women who have become pregnant within the first month after exposure to GYNECARE INTERCEED®. No teratogenic studies have been performed. Therefore, avoidance of conception should be considered during the first complete menstrual cycle after use of GYNECARE INTERCEED®. The safety and effectiveness of using GYNECARE INTERCEED® in combination with other adhesion prevention treatments have not been clinically established. GYNECARE INTERCEED® is supplied sterile. As the material is not compatible with autoclaving or ethylene oxide sterilization, GYNECARE INTERCEED® must not be resterilized. Foreign body reactions may occur in some patients. Interactions may occur between GYNECARE INTERCEED® and some drugs used at the surgical site. Pathologists examining sites of GYNECARE INTERCEED® placement should be made aware of its usage and of the normal cellular response to GYNECARE INTERCEED® ‘to facilitate proper evaluation of specimens'.
    The type and frequency of adverse events reported are consistent with events typically seen following surgery. Postsurgical adhesions may occur in the presence of GYNECARE INTERCEED®.