ECHELON FLEX™ Powered Vascular Stapler

Only the ECHELON FLEX™ Powered Vascular Stapler with Advanced Placement Tip gives you a narrower anvil, thinner shaft and more articulation than Endo GIA™ Curved Tip Reload with Tri-Staple™ Technology.

Incredibly precise

Narrower anvil,§ thinner shaftβ and more articulation¥

Watch a PV Transection during Right Upper Lobectomy with ECHELON FLEX™ Powered Vascular Stapler. Watch Dr. Zane Hammoud at Henry Ford Hospital in Detroit, MI perform a PV transection during a right upper lobectomy procedure with ECHELON FLEX Powered Vascular Stapler.

Download product brochure  picture_as_pdf

Superior maneuverability

26% narrower curved, blunt tip anvil vs. Endo GIA™ Reload with Tri-Staple™ Technology

Reduce the amount of dissection required around the vessel to place the stapler. Plus, the blunt, curved tip improves visibility and confirms early, precise placement on thoracic vessels.

View white paper  picture_as_pdf
ECHELON FLEX™ Powered Vascular Stapler

More flexibility during placement

11% greater manual articulation in each direction* vs. Endo GIA™ Reload with Tri-Staple™ Technology

Only the Powered Vascular Stapler provides a span of 100° (50° in each direction), which may make it easier to navigate in the tight thoracic cavity.

Download instructions for use guide  picture_as_pdf

Increased freedom of movement

The 9mm shaft, which is 26% thinner, offers an unprecedented angle of reach

Thinnest shaft diameter offers an unprecedented angle of reach for 43.8% greater freedom of movement in the tight intercostal space.

Contact a representative  assignment_ind
ECHELON FLEX™ Powered Vascular Stapler

ECHELON FLEX™ Powered Vascular Stapler

PRODUCT CODE DESCRIPTION QUANTITY SALES UNIT
PVE35A 35mm Standard Articulating Endoscopic Linear Cutter,* 320mm 3
RELOAD CODE DESCRIPTION RELOAD COLOR NUMBER OF STAPLED ROWS OPEN STAPLE HEIGHT CLOSED STAPLE HEIGHT QUANTITY SALES UNIT
VASECR35 White reload intended for use in vascular/thin tissue White 4 2.5mm 1.0mm 12
* Instrument does not contain a reload

RELATED PRODUCTS


Site References

  • * Based on articulation data from IFUs of each device
  • Approach angles assessed in a virtual CAD environment in the 5th intercostal space.
  • Compared to the EndoGia Curved Tip and the ECHELON FLEX™ Powered ENDOPATH® 45mm Stapler [as evaluated by surgeons in questionnaire following usage in animate porcine labs] (p<0.05 for both devices).
  • § Versus leading staplers on the market as of October 2014.
  • β Compared to Endo GIA™ Reload with Tri-Staple™ Technology.
  • ¥ Compared to Endo GIA™ Reload with Tri-Staple™ Technology. Based on articulation data from IFUs of each device.
X
Thanks for submitting the question. Thanks for submitting the question. Thanks for submitting the question. Thanks for submitting the question. on dev
X
Share with Friends

Interested in sharing this item?

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Image CAPTCHA
Enter the characters shown in the image.
X
Device Code Translator
X
Device code translator results

Back to Search